94
SECTION 5
Parameter
Settin
gs
in DM
Area
RFID System
User's Manual
SECTION 5
ID Sensor Unit Functions
Verification Setting
Verification can be enabled for write operations, or verification can be disabled to shorten the
communications time. The verification setting is valid for all commands except for Read and Data
Check with a processing specification of verification.
Communications Speed Setting
High-speed communications can be set whenever the communications method is set to trigger, single
auto, or repeat auto.
• First word allocated to Unit in DM Area: m = 100
×
Unit number
After setting DM Area data with the Support Software, reset the power supply to the PLC or turn ON the Special I/O Unit Restart
Bit. The DM Area settings will be transferred to the ID Sensor Unit when the power supply turns ON or when the Special I/O Unit
Restart Bit is turned ON.
DM Area address
Bit No.
Description
Default
Antenna 1 of
CS1W-V680C11,
CS1W-V680C12,
CJ1W-V680C11,
or
CJ1W-V680C12
Antenna 2 of
CS1W-V680C12
or
CJ1W-V680C12
m
m+100
04 to 07
0
Verify write operations.
0
(Verification)
1
Do not verify write operations.
DM Area address
Bit No.
Description
Default
Antenna 1 of
CS1W-V680C11,
CS1W-V680C12,
CJ1W-V680C11,
or
CJ1W-V680C12
Antenna 2 of
CS1W-V680C12
or
CJ1W-V680C12
m
m+100
00 to 03
0
Communications speed setting: Normal
0
(normal)
1
Communications speed setting: High speed
Summary of Contents for CJ1W-V680C11