30
SE
C
T
IO
N
2
Spec
if
ic
at
io
ns
RFID System
User's Manual
SECTION 2
CS-series ID Sensor Units
Specifications
General Specifications
General specifications conform to those of SYSMAC CS-series Special I/O Units.
Performance Specifications
Note 1.
“Rack” indicates either the CPU Rack or an Expansion Rack.
2.
The V680-H01 Antenna can be connected only to the CS1W-V680C11 ID Sensor Unit.
It cannot be used with the CS1W-V680C12 ID Sensor Unit.
3.
If using Intelligent I/O Instructions is specified as the data transfer method, up to 2,048 bytes can be
transferred in one scan.
CS1W-V680C11
CS1W-V680C12
Unit classification
Special I/O Unit
Influence on CPU
Unit's cycle time
0.15 ms
0.3 ms
External power supply
---
24 VDC +10%/-15%, 360 mA
Internal current
consumption
V680-HA63
@
Amplifier connected: 5 VDC, 260 mA
24 VDC, 125 mA
V680-H01 Antenna connected: 5 VDC, 260 mA
24 VDC, 280 mA
5 VDC, 320 mA
24 VDC, 0 mA
Dimensions
35 x 130 x 101 mm (W x H x D)
Weight
180 g max.
300 g max.
Mounting location
CS-series CPU Rack or CS-series Expansion Rack
(Cannot be mounted to C200H Expansion I/O Racks or SYSMAC BUS Slave Racks.)
No. of Units per Rack
V680-HA63
@
Amplifier connected: 5 per Rack
V680-H01Antenna connected: 2 per Rack
(See note 1.)
10 per Rack
(See note. 1)
Connectable Antennas
(See note 2.)
V680-series Amplifiers (V680-HA63
@
)
V680-series Antennas (V680-H
@@
)
One channel
V680-series Amplifiers (V680-HA63
@
)
V680-series Antennas (V680-H
@@
)
One or two channels
Applicable RF Tags
V680-series RF Tags (V680-D
@@
)
No. of allocated unit
numbers
1
2
No. of allocated words
10 words
20 words
Control protocol
Special protocol
Data exchange
methods with CPU Unit Special I/O Unit Area in
CIO Area: CIO 2000 to
CIO 2959
Constant data exchange
of 10 words/Unit
CPU Unit to
ID Sensor Unit
Unit controls, communications
processing specification,
data storage area specification
ID Sensor Unit to
CPU Unit
Unit information, results information,
processing results monitor
Special I/O Unit words in
DM Area: D20000 to
D29599
100 words/Unit
transferred when power
is turned ON or when
restarting the Unit
CPU Unit to ID
Sensor Unit
System Settings, Auto Wait Time
Setting, Write Protection Disable
Setting, Antenna Connection Setting,
Results Monitor Output, Test Setting,
Run/Test Switching Method Setting
Data transfer quantity
2,048 bytes max. (160 bytes/scan) (See note 3.)
2,048 bytes max./channel (160 bytes/scan) (See note 3.)
Operating modes
Run Mode
Test Mode
·
Communications tests
·
Range level measurements
·
Read speed level measurements
·
Write speed level measurements
·
Noise level measurements
·
Communications success rate measurements
Diagnostic function
(1) CPU watchdog timer
(2) Communications error detection with RF Tag
(3) Antenna power supply error
Summary of Contents for CJ1W-V680C11
Page 213: ......