150
SE
C
T
ION 7
ID Senso
r Un
it
Al
arms
RFID System
User's Manual
SECTION 7
Troubleshooting Alarms and Errors
Note 1:
The following errors may occur while writing for a Copy command. Confirm the steps to handle each error.
• RF Tag communications error
• RF Tag verification error
• RF Tag missing error
• RF Tag address error
• Antenna error
• Write protection error
Note 2:
CIO n+8, CIO n+9 are error information of Antenna 1 (Head No.1).
CIO n+18, CIO n+19 are error information of Antenna 2 (Head No.2).
Error name
Word
(CIO n+8)
(CIO n+18 (See note.2))
Word
(CIO n+9)
(CIO n+19 (See note.2))
Error
Correction
RF Tag
Communications
Error Flag
Bit 12
E070
An error occurred in communications
with a RF Tag, preventing a normal
end.
• Check for excessive noise.
• Check the travel speed.
• Check the distance between the
Antenna and RF Tag.
Verification Error
Flag
Bit 14
E071
The correct data could not be written
to the RF Tag.
(Occurs only when verification is set
for a write operation.)
• Check the travel speed. (Page 143)
• Check for excessive noise.
RF Tag Missing
Error Flag
Bit 10
E072
• The communications specification
was for a trigger, but there was no
RF Tag in the interrogation zone.
• The communications specification
was for single auto, but the Auto
Wait Time expired.
• The Antenna and RF Tag are too
far apart.
• The axis is out of alignment.
ID System Error 1
Bit 09
E079
System error
Please consult your OMRON
representative.
ID System Error 2
Bit 08
E07E
System error
Please consult your OMRON
representative.
ID System Error 3
Bit 07
E07F
System error
Please consult your OMRON
representative.
Status Flag
Bit 04
E076
• An overflow or underflow occurred
for a Calculation Write command.
• The data did not verify for a Data
Check command.
• The number of writes was
exceeded for a Number of Writes
Control command.
• An error occurred in the data for a
Read with Error Correction command.
• Check the data settings.
• Replace the RF Tag.
• An error occurred while writing for a
Copy command.
(See note.1)
RF Tag Address
Error Flag
Bit 13
E07A
The RF Tag address specified in the
command is not correct.
• Specify the address correctly.
Antenna Error Flag
Bit 15
E07C
An Antenna error occurred.
• Check 24 VDC input.
(CS1W-V680C12 only)
• Check the Antenna.
Write Protection
Error Flag
Bit 11
E07D
An attempt was made to write to a
write-protected area.
• Specify the address and number of
bytes correctly.
• Clear write protection. (Page 95)
Error Correction
Flag
Bit 03
E077
Read with Error Correction
performed a 1-bit error correction.
---
Data Storage Area
Specification Error Flag
Bit 01
E014
The data storage area specification
is not correct.
Specify the data storage area
specification correctly.
Command Error
Flag
Bit 00
E014
The command to the ID Sensor Unit
is not correct.
Specify the command correctly.