EM-7807-AJ  P. 1 / 8

INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

Totalized pulse input module .............................................(1)

 

MODEL NO.

Confirm Model No. marking on the product to be exactly
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.

POINTS OF CAUTION

 

POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product and

confirm its operational range as indicated below:

24V DC rating: 24V ±10%, approx. 80mA

 

GENERAL PRECAUTIONS

• Before you remove the unit or mount it, turn off the power 

supply and input signal for safety.

• Before you remove the terminal block or mount it, turn off 

the power supply and input signal for safety.

• DO NOT set the switches on the module while the power

is supplied.  The switches are used only for maintenance
without the power.

 

ENVIRONMENT

• Indoor use.
• When heavy dust or metal particles are present in the

air, install the unit inside proper housing with sufficient
ventilation.

• Do not install the unit where it is subjected to continuous

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -10 to +55°C

(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.

 

WIRING

• Do not install cables close to noise sources (relay drive

cable, high frequency line, etc.).

• Do not bind these cables together with those in which

noises are present.  Do not install them in the same duct.

• Be sure to close the terminal cover for safety.

 

AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.

TOTALIZED PULSE INPUT MODULE, 8 points

(Ethernet Modbus/TCP)

MODEL

R7E-PA8

056 222 38 18

[email protected]

www.sentronic.com

SENTRONIC

AG

Summary of Contents for R7E-PA8-R

Page 1: ...y and input signal for safety DO NOT set the switches on the module while the power is supplied The switches are used only for maintenance without the power ENVIRONMENT Indoor use When heavy dust or m...

Page 2: ...signal status ON LED ON OFF LED OFF OPERATING MODE Extension SW1 1 1 2 SW1 1 SW1 2 EXTENSION OFF OFF No extension ON OFF Discrete input 8 or 16 points OFF ON Discrete output 8 or 16 points Factory set...

Page 3: ...76 7 sec 180 0 sec CHANNEL INDIVIDUAL SETTING PARAMETER SETTING RANGE DEFAULT SETTING Max 1 000 4 294 967 295 9 999 999 Carry 0 1 0 Preset 0 4 294 967 295 EXTENSION MODULE SETTING PARAMETER SETTING RA...

Page 4: ...V PI0 C0 18 PI7 9 C7 1 10 2 11 V V PI0 C0 1 5 10 2 6 4 7 13 8 9 14 12 15 11 16 17 18 V V C1 C2 C3 C4 C5 C6 C7 PI0 PI7 PI1 PI2 PI3 PI4 PI5 PI6 C0 3 PNP connection NPN connection Input Connection Examp...

Page 5: ...4 Reply from bytes 32 time 10ms TTL 64 Reply from bytes 32 time 10ms TTL 64 Ping statistics for Packets Sent 4 Received 4 Lost 0 0 loss Replies in case of normal connection are as shown above If the c...

Page 6: ...write data upper 21 CH 2 Return value read data upper 22 CH 2 Return value write data lower 22 CH 2 Return value read data lower 23 CH 3 Return value write data upper 23 CH 3 Return value read data up...

Page 7: ...pe RUN status EXCEPTION CODES CODE NAME 01 Illegal Function Function code is not allowable for the slave 02 Illegal Data Address Address is not available within the slave 03 Illegal Data Value Data is...

Page 8: ...MINAL Torque 0 5 N m SOLDERLESS TERMINAL Refer to the drawing below for recommended ring tongue terminal size Spade tongue type is also applicable Applicable wire size 0 25 to 1 65 mm2 AWG 22 to 16 Re...

Reviews: