![Odetics Telecom GPStarplus 365 User Manual Download Page 66](http://html1.mh-extra.com/html/odetics-telecom/gpstarplus-365/gpstarplus-365_user-manual_3340678066.webp)
Odetics
Telecom
GPStar
plus
Model 365
365-8006
Display Menus and Controls 5 - 9
5.4
DETAILED SCREEN DESCRIPTIONS
The remainder of this section describes in detail the information displayed on each of
the operating screens and how the user can change
operating parameters.
5.4.1
MENU 1 - TIME
There are five main screens associated with Menu 1. Several screens are editable.
•
Press key 1 until Menu 1 of 5 is selected (
Time, Date, Status, Satellites
)
GPS TFOM 4 May 26,1999 / 145:21:54:28
≡
Time Locked Sats:26a 12
≡
15a 28
≡
22s
This screen displays the general operating status of the unit:
•
Synchronization Mode (Manual or synchronized to UTC/GPS time)
•
Time Reference Mode
•
Accuracy (Time Figure of Merit) of timing output
•
Current date and time
•
Synchronization status
•
Satellite tracking information
5.4.1.1
Synchronization Mode Selection
Normal Mode
- Under normal operating conditions the time computed by the GPS
receiver, if valid, is transferred to internal unit's master clock that is driven by the
internal disciplined oscillator.
Manual Time Mode
- When Manual Time Mode is enabled, the internal oscillator is
allowed to free-wheel (not disciplined). This would only be used if the user suspects
that the receiver is providing an invalid time reference.
When Manual Time Mode is enabled, the user can specify the time and date.
However, when time transfer is re-enabled, the GPS receiver will automatically set the
time and date.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com