Specifications 2 - 29
2.7.8.4
13 MHz Sinusoid Output (Other Option -4)
Other Option -4 provides a 13 MHz sinusoid output. This output is phase-locked to the
unit's internal precision 10 MHz disciplined oscillator. The output is present in all
modes of operation.
Connector Identification................................................................... 13 MHz
Connector Type ........................................................................ BNC female
Wave Shape .................................................................................. Sinusoid
Frequency Accuracy .....................................................Same as Reference
Frequency Output (Paragraph 2.7.1)
Amplitude........................................................................+16.8, +/- 1.0 dBm
(3.9 Vpp to 4.9 Vpp into a 50
Ω
load
Spectral Purity
2nd Harmonic ............................................................................- 55dBc
3rd Harmonic .............................................................................- 48 dBc
Other Harmonics and Non-Harmonic
- 62 dBc
Phase Noise (Maximum).................................................< - 68 dBc @ 1 Hz
(Bandwidth = 1 Hz)
< - 70 dB @ 10 Hz
< - 75 dBc @ 100 Hz
< - 85 dBc @ 1 kHz
< - 110 dBc @ 10 kHz - 100 kHz
Coupling ................................................................................................. AC