The LMT lamp lights up to show that the unit is currently in limit display state.
When the lamp is off, the unit is in ReadBack Display (actual output voltage/current) mode.
The procedure below is for setting the limit display.
*Limit Display in Output OFF mode
▌Turn on the power switch.
After turning on power, check if the unit is in "**OUTPUT OFF**" mode.
▌Press the Limit Display key to view the voltage and current limitations.
▌The LMT lamp lights up, and the LCD shows the currently set voltage and
current values.
Displayed LCD Message
00.00V 88.00A
▌By using the cursor keys and encoders in this state, the voltage and current
settings can be changed.
▌Press the IO/Local key once more
to disable the voltage and current settings mode.
Displayed LCD Message
**output off**
*Limit Display in Output ON mode
▌Turn on the power switch.
After turning on power, check if the unit is in "**OUTPUT OFF**" mode.
▌Press the Output ON/OFF key for voltage and current output.
Displayed LCD Message
00.00V 00.00A
▌Press the Limit Display key to view the voltage and current limitations.
▌The LMT lamp lights up, and the LCD shows the currently set voltage and
current values.
Displayed LCD Message
00.00V 88.00A
▌By using the cursor keys and encoders in this state, the voltage and current
settings can be changed.
▌Press the IO/Local key once more
to disable the voltage and current settings mode.
Displayed LCD Message
10.00v 00.00a
This example set the voltage to 10V
- 43 -
Summary of Contents for MX Series
Page 61: ...57...