Delimiter
You can choose the transferred data’s terminal code as LF, CR, or CRLF. The default setting at the
time of shipment from the factory is LF. The procedure for this setting is described below.
▌Turn on the power switch.
After turning on power, check if the unit is in "**OUTPUT OFF**" mode.
▌Press the IO/Local Key to change the delimiter.
Displayed LCD Message
This can be different depending on
the previous state.
▌Press the cursor key to show “
5.delimiter
.”
Displayed LCD Message
▌Press the IO/Local key to change the settings to CR.
Displayed LCD Message
This can be different depending on
the previous state.
▌Press the cursor key to select CR.
After pressing the cursor key to show “
delimiter cr
,” press the IO/Local
key to save your settings.
Displayed LCD Message
Response
You may receive a response from the device when transmitting setting orders. This is unlocked at
the time of shipment from the factory. The procedure for this setting is described below.
▌Turn on the power switch.
After turning on power, check if the unit is in "**OUTPUT OFF**" mode.
▌Press the IO/Local Key to change the response.
Displayed LCD Message
This can be different depending on
the previous state.
▌Press the cursor key to show “
6.response
.”
Displayed LCD Message
▌Press the IO/Local Key to receive a response.
Displayed LCD Message
This can be different depending on
the previous state.
▌Press the cursor key to show “YES.”
After pressing the cursor key to show
“response yes,” press the IO/Local
key to save your settings.
Displayed LCD Message
3-12. Limit Display
This key is for viewing the currently set voltage and current.
- 42 -
I/O>
>delimiter lf
delimiter
delimiter
>response
I/O>
I/O>
response yes
SAVED