3-1. Activating Constant Voltage (CV)
▌Turn on the power switch.
After turning on power, check if the unit is in "**OUTPUT OFF**" mode.
▌Connect the DUT to the output terminals.
▌Press the LMT DISPLAY Key to set the limit.
▌You can protect the DUT from damage by setting the current value a bit higher than
▌To set the current value, use the right cursor key and encoder.
▌If all settings are complete, press the OUTPUT ON/OFF Key to approve the output.
The unit will then switch to Readback Display mode.
▌Check if the CV lamp is on while the CC lamp is off.
If the CC lamp is on and the CV lamp is off, check if the current provided for the
DUT is enough and increase the current limit value.
≫ Related remote interface commands
APPLy{<voltage>,<current>}
VOLT{<voltage>|UP|DOWN}
CURR{<current>|UP|DOWN}
OUTP{OFF|ON}
Application1:
OUTP OFF Disable Output
OUTP OFF
Disable Output
VOLT 10
Set Voltage to 10V
APPLY 10,5
Set for 10V/5A
CURR 5
Set Current to 5A
OUTP ON
OUTP ON Output Voltage and Current
1. The left cursor key increases the voltage range, and the right cursor key decreases the current rang
2. What is ReadBack Display?
This means that the LCD is displaying the currently outputted voltage and current.
- 20 -
The procedure for activating constant voltage output mode is described below.
(The last state mode is disabled in this example.)
the current value a bit higher than the amount of current required by DUT.
Change the current settings below as well.
The current cannot exceed the protection level if the Protection (OCP/UCL/OCL)
settings are active.
If you try to exceed the limit in this case, the “
PROTECTION LIMIT
” message
will be displayed, and the current will be set to the protection level’s value.
▌When setting the voltage, use the left cursor key to move the cursor to the
desired voltage
range, and then use the encoder switch to select your desired voltage.
The voltage cannot exceed the protection level if the Protection (OVP/UVL/OVL)
settings are active. If you try to exceed the limit in this case, the
“
PROTECTION
LIMIT
”
message will be displayed, and the voltage will be set to the protection
Application 2: