and pressing the Enter key.
where
active_cpk
is the number of the previously inactive circuit pack
13
Protection switch back to the original circuit pack by typing
>MANUAL <active_cpk> <inactive_cpk>
and pressing the Enter key.
where
active_cpk
is the number of the previously inactive circuit pack
inactive_cpk
is the number of the previously active circuit pack
Note:
For CEMs, the active_cpk and spare_cpk parameters
are not required.
14
Return to the posted circuit pack by typing
>QUIT
and pressing the Enter key.
15
List the alarms on the module by typing
>LISTALM
and pressing the Enter key.
16
Determine whether the alarm has cleared.
17
Perform an in-service test on the module by typing
>TST
and pressing the Enter key.
Example of a MAP screen:
18
Determine the test condition of the module.
19
Access the PROT level by typing
>PROT
SPM 3 OC3 1 Act ISTb
Loc : Row E FrPos 8 ShPos 24 ShId 0 Slot 10 Prot Grp : 1
Default Load: SPMLOAD Prot Role: Spare
Clock:Input Ref: Internal Source: C Side 0 Current Mode:
Acquire
Tst
SPM 3 CEM 0 Test : Request has been submitted.
SPM 3 CEM 0 Test : Test passed.