NN10078-911 SN06.2 Preliminary 02.03 March 2004
17
Copyright © 2004, Nortel Networks
Nortel Networks Confidential
4
Select the ISTb common equipment module (CEM) by typing
>SELECT CEM <cem_no>
where
cem_no
is the number of the ISTb CEM (0 or 1)
Example of a MAP screen:
5
List the alarms on the CEM by typing
>LISTALM
and pressing the Enter key.
Example of a MAP screen:
6
Record the number of each SPM exhibiting the CLKOOS
condition.
7
Access the MTC level of the MAP screen by typing
>MAPCI;MTC
and pressing the Enter key.
SPM 11 CEM 0 Act ISTb
Loc : Row F FrPos 64 ShPos 6 ShId 0 Slot 7
Default Load: SPMLOAD
Clock:
Input Ref: Source: Current Mode:
SPM 11 CEM 0 Act ISTb
Loc : Row F FrPos 64 ShPos 6 ShId 0 Slot 7
Default Load: SPMLOAD
Clock:
Input Ref: Source: Current Mode:
ListAlm
ListAlm: SPM 11 CEM 0
SEVERITY ALARM ACTION
––––––––––––––––––––––––––––––
Critical None
Major CLKOOS RPT
Minor None