IW SPM IP Fault Management
Nortel Networks Confidential
32
Copyright © 2004, Nortel Networks
b
Create a heading for the tuple by typing
>HEADING
and pressing the Enter key.
c
Position on the tuple for the ENET shelf by typing
>POS <enet_shelf_no>
and pressing the Enter key.
where
enet_shelf_no
is the number of the ENET shelf
Example of a MAP screen:
d
Record the MS card numbers under
MSCARD0
and
MSCARD1
(
6
and
10
in the example above).
11
Locate the MS cards by typing
>MAPCI;MTC;MS;SHELF 0;CARD <ms_card_no>
and pressing the Enter key.
where
ms_card_no
is the number of the MS card
Example of a MAP screen:
CI:
>table eninv
MACHINES NOT IN SYNC – DMOS NOT ALLOWED
JOURNAL FILE UNAVAILABLE – DMOS NOT ALLOWED
TABLE: ENINV
>heading
ENKEY ENCLASS FRTYPE FRNO FRPEC SHPEC MSCARD0 MSLINK0 MSPORT0 FLOOR0
ROW0 FRPOS0 SHELF0 LOAD0 MSCARD1 MSLINK1 MSPORT1
FLOOR1 ROW1 FRPOS1 SHELF1 LOAD1
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
>pos 0
0 PRI ENC 0 NT9X05AB NT9X0801 6 0 0 1
F 2 39 ENX08AX 10 0 0
1 F 1 39 ENX08AX