8
Return to the SPM screen and wait for the CEM to change to the
manual busy (ManB) state.
Note:
The state change to ManB may take several minutes to
complete.
At the CEM screen
9
Before removing the CEM card, you must change the state of the
ENET links to ManB. Perform the following substeps to record
the applicable ENET information:
a
List the ENET links by typing
>TRSL
and pressing the Enter key.
Example of a MAP screen:
Note:
In this example, the dual self configuration for X and
Y are two different shelves, and the single shelf
configuration for X and Y is one shelf.
b
Record the ENET plane, shelf, and slot number (
0,X,14
and 1,X,14
in the example above).
10
Go to the ENET level of the MAP by typing
>MTC;NET
and pressing the Enter key.
The following is an example of an ENET screen.
SPM 11 CEM 0 InAct ManB /
Loc : Row C FrPos 4 ShPos 6 ShId 0 Slot 7
Default Load: SPMnnnn
Clock:
Input Ref: Source: Current Mode:
Trnsl
Link 1: ENET 0 X 14 0; Status: OK
Link 2: ENET 0 X 14 1; Status: OK
Link 3: ENET 0 Y 14 2; Status: OK
Link 4: ENET 0 Y 14 3; Status: OK