NN10078-911 SN06.2 Preliminary 02.03 March 2004
12
Copyright © 2004, Nortel Networks
Nortel Networks Confidential
Log SPM300 Problem Descriptions
The following table provides details for the problem descriptions in the
SPM300 log.
Log SPM332 Problem Descriptions
The following table provides details for the problem descriptions in the
SPM332 log.
SPM300 log problem descriptions
Failure reason
Explanation
Check messaging:
Inactive CEM to RM
loopback test
timeout
This log indicates that there is a problem communicated to the
indicated RM from the inactive CEM. If the inactive CEM
becomes active while this condition exists, the RM will go
SYSB.
If this log occurs:
1) Collect sysbuf and /aer/display all from the inactive CEM
dshell.
2) Try to remlogin to the RM from the inactive CEM. If this fails,
remlogin to the RM from the active CEM. Collect the footprint
logs from the RM.
3) BSY/RTS the RM.
4) If the log reoccurs, BSY/RESETMOD/RTS the inactive
CEM.
SPM332 log - REX test failure
Failure reason
Explanation
Node not in InSv/IsTb state
Stability check on node failed.
<Node state> state
SPM REX aborted
CEM not in InSv state, RM
not in InSv/MANB/OFFL state
Stability check on <CPK type> <CPK no:> failed.
<CPK state> state
SPM REX aborted
CEM/RM having a non-state
alarm
Stability check on <CPK type> <CPK no:> failed.
<Alarmid> alarm
SPM REX aborted