IW SPM IP Fault Management
Nortel Networks Confidential
5
Copyright © 2004, Nortel Networks
IWBM803
Number of available IW bridges falls to less than 85% of bridges in
the pool in use. This log always occurs after IWBM802. Does not
include offline carriers.
IWBM900
Nortel design debug tool.
LINK300
A DS-512 hostlink is detected as misconnected between the ENET
and the SPM-CEM.
Check to find out which links are misconnected.
•
BSY the links from the ENET map
•
Connect the links from the ENET to correspond correctly with the
CEM. The port on the CEM must be exactly as datafilled in table
MNLINK.
•
RTS the MANB links from the ENET map
Note:
Refer to solution level logs to see other possible causes for
the LINK300 log
LINK500
Logs generated from the MS and ENET for the DS-512 links.
NODE300
Logs related to hardware faults in the RMs and CEM.
Refer to log NODE303 below.
NODE302
Software Alarm
NODE303
Logs to indicate Wrong Application Data on the CEM.
Core Integrated Node Maintenance (INM) detected wrong
application data for one of the following reasons:
•
CEM restarted with wrong application data due to manually
initiated Reset/Loadmod/InsvLD.
•
CEM restarted with wrong application data due to system
initiated Reset/Loadmod.
•
Manual/system initiated RTS (bringing CEM back into service -
INSV/ISTB) was attempted on CEM with wrong application data.
Note 1:
for NODE303
format details.
Note 2:
See log Link300 (above) to help identify the misconnected
DS-512 Link.
IW SPM IP fault management indicators
Log name
and number
Explanation