NN10078-911 SN06.2 Preliminary 02.03 March 2004
Nortel Networks Confidential
59
Copyright © 2004, Nortel Networks
MANB
SPM300,
SPM331,
SPM500,
SPM630
A device on the SPM is in a manual busy state.
Indicates RM has gone into MANB state due to
manual maintenance from the MAP interface.
MANBNA
SPM600
The SPM is in ManB state and is isolated from
the ENET links or the MS ports.
NOSPARE
SPM300,
SPM331
The last spare module in a protection group is
not available for service.
PROTFAIL
SPM300,
SPM331,
SPM500
Protection switching failed for an RM.
SYSB
NODE500,
SPM300,
SPM331,
SPM500,
SPM630
A device on the SPM is in a system busy state.
Indicates RM has gone into SYSB state due to
loss of communications or hardware fault.
SYSBNA
ENET311
The SPM node is system busy and not
accessible, and a network error has caused it to
be isolated from the ENET links or the MS
ports.
SPM alarm to log correlation
Alarm
Related logs
Probable cause