IW SPM IP Fault Management
Nortel Networks Confidential
54
Copyright © 2004, Nortel Networks
Allowing/inhibiting alarm reporting
Alarm reporting is configured via datafill. Datafilling an alarm with a
“RPT” option allows alarm reporting. The “NRPT” option inhibits alarm
reporting. The procedure that follows shows an example of datafilling
the COTLOW and MFLOW alarms in table MNNODE. The COTLOW
alarm is configured to be reported, while the MFLOW alarm is
configured to not be reported.
Example of alarm reporting configuration
At the MAP level
1
Access table MNNODE by typing
>TABLE MNNODE
and pressing the Enter key.
2
Begin the table addition by typing
>ADD
and pressing the Enter key.
3
Answer each of the prompts with the required datafill provided by
the table range.
Example
This is an example of datafilling table MNNODE.
>ADD
ENTER Y TO CONTINUE PROCESSING OR N TO QUIT
>Y
NODEKEY:
>SPM 1
ALIAS:
>ALARMREPORTS
CLASS:
>DMSCP
FLOOR:
>0
CLKMODE:
>SYNC