IW SPM IP Fault Management
Nortel Networks Confidential
82
Copyright © 2004, Nortel Networks
15
Translate the peripheral-side links of the ENET by typing
>TRNSL P <plane_no> <link_no>
and pressing the Enter key.
where
plane_no
is the number of the ENET plane (0 or 1)
link_no
is the number of an ENET link (0 to 3)
Example of a MAP screen:
Repeat the TRNSL P command to determine all four ENET
P-side links to the CEM being replaced. Record the link
connections. The following example shows the ENET links for a
typical dual-shelf SPM connection.
ENET links for a typical dual-shelf SPM connection
ENET Plane
Link
SPMCEM
Link
0
0
0
1
0
1
0
2
0
2
0
3
0
3
0
4
1
0
1
1
1
1
1
2
SHELF
00
Slot 1111111 11122222 22222333 333333
123456 78 90123456 78901234 56789012 345678
Plane 0
. . .F ......F. –––––––– ...S.... . .
Plane 1
. . .F ......F. –––––––– ..FS.... . .
CARD
14
Front: Back: DS–512 Links
Xpt I/F
0 1 2 3
Plane 0
. . . . . .
Plane 1
. . . . . .
CARD:
Request to TRNSL ENET Plane:0 Shelf:00 Slot:14 Link:00 submitted.
Request to TRNSL ENET Plane:0 Shelf:00 Slot:14 Link:00 passed.
ENET Plane:0 Shelf:00 Slot:14 Link:00 :
SPM 11 CEM 0 Lnk 1