IW SPM IP Fault Management
Nortel Networks Confidential
50
Copyright © 2004, Nortel Networks
7
Return the ENET links to service. When you have completed the
procedure, return to this point.
Note:
Contact your next level of support if you are not familiar
with the procedures required to restore ENET links to service.
8
List the alarms on the SPM unit by typing
>LISTALM
and pressing the Enter key.
9
Perform the following substeps to record ENET information:
a
List the status of the ENET links by typing
>TRNSL
and pressing the Enter key.
Example of a MAP screen:
b
Record the ENET shelf number (
30
in the example above).
10
Do the following substeps to detemine the MS card numbers:
a
At the CI level of MAP screen, locate the MS card that the
ENET is connected to by typing
>TABLE ENINV
and pressing the Enter key.
b
Create a heading for the tuple by typing
>HEADING
and pressing the Enter key.
If the alarm list shows
Do
None
Step
SYSBNA
Step
SPM 11 CEM 0 Act SysB (NA)
Loc : Row F FrPos 64 ShPos 6 ShId 0 Slot 7
Default Load: SPMLOAD
Clock:
Input Ref: Source: Current Mode:
Trnsl
Link 1: ENET 0 0 30 0; Status: OK
Link 2: ENET 1 0 30 1; Status: NA
Link 3: ENET 0 0 30 2; Status: OK
Link 4: ENET 1 0 30 3; Status: OK