23
Wait until the card performs a self-test (less than one minute).
The self test is complete when the green LED remains on and
the red LED remains off. If both LEDs stay on for an extended
period of time, it means the replacement card is defective;
remove the card and replace it with another replacement card. If
both LEDs remain on with the second replacement card, contact
your next level of support.
24
Reconnect the cable from the faceplate of the card.
25
Close the cable trough door. Close and lock the card-access
door.
At the MAP terminal
26
Return to the GEM screen and take the card from the OffL state
to ManB state by typing
>BSY
27
Load the new card with the default software load by typing
>LOADMOD
Monitor the progress of the loading activity on the SPM line of
the screen.
28
Return the new card to Insv state by typing
>RTS
Note:
The state change from ManB to Insv can take up to
seven minutes to complete.