NN10078-911 SN06.2 Preliminary 02.03 March 2004
37
Copyright © 2004, Nortel Networks
Nortel Networks Confidential
9
Return to the module level and set the module to manual busy
by typing
>QUIT;BSY;RTS
and pressing the Enter key. Go to Step 11.
10
Return to the module level and return the module to service by
typing
>QUIT;RTS
and pressing the Enter key.
11
List the alarms on the module at the protection level by typing
>PROT;LISTALM
and pressing the Enter key.
Example of a MAP screen:
If the module is
Do
OffL
Step
ManB
Step
in any other state
Step
SPM 16 InSv
Prot Grp: VSP_GRP 1 Mode: Non–revertive Schema: m_for_n
Sh0 U R A Stat Sh0 U R A Stat Sh1 U R A Stat Sh1 U R A Stat
1
–– – – ––––
8
–– – – ––––
1
0 W A ManB
8
–– – – ––––
2
–– – – ––––
9
–– – – ––––
2
1 W A ManB
9
–– – – ––––
3
–– – – ––––
10
–– – – ––––
3
–– – – ––––
10
–– – – ––––
4
–– – – ––––
11
–– – – ––––
4
–– – – ––––
11
–– – – ––––
5
–– – – ––––
12
–– – – ––––
5
–– – – ––––
12
–– – – ––––
6
–– – – ––––
13
–– – – ––––
6
–– – – ––––
13
–– – – ––––
7
–– – – ––––
14
–– – – ––––
7
–– – – ––––
14
–– – – ––––
ListAlm
ListAlm: VSP_GRP 1
SEVERITY ALARM ACTION
––––––––––––––––––––––––––––––
Critical None
Major NOSPARE RPT
Minor None
No_Alarm None