At the MAP terminal:
35
Return-to-service (RTS) the four ENET links to the replacement
CEM by typing
>RTS <plane_no> LINK <link_no>
and pressing the Enter key.
where
plane_no
is the number of the ENET plane (0 or 1)
link_no
is the number of an ENET link (0 to 4)
Repeat the RTS command for each link to the replacement
CEM.
36
At the CEM screen, reset the replacement CEM card by typing
>RESETMOD FW
and pressing the Enter key.
Wait until the MS ports clear and the maintenance activity
completes.
37
Post the SPM by typing
>MAPCI;MTC;PM;POST SPM <spm_no>
and pressing the Enter key.
spm_no
is the number of the SPM (0 to 85)
38
Select the CEM by typing
>SELECT <cem_no>
and pressing the Enter key.
where
cem_no
is the CEM number (0 or 1)
39
Lload the replacement CEM card by typing
>LOADMOD
and pressing the Enter key.
Note:
The LOADMOD process can take up to 15 minutes to
complete. Monitor the progress at the
/Load:
indicator at the
end of the SPM line on the CEM MAP display.