NN10078-911 SN06.2 Preliminary 02.03 March 2004
31
Copyright © 2004, Nortel Networks
Nortel Networks Confidential
7
If the status of the ENET links is
NA
(not available), Determine
whether they were manual busied and why. Return the ENET
links to service as soon as possible. When you have completed
the procedure, return to this point.
Note:
Contact your next level of support if you are not familiar
with the procedures required to restore ENET links to service.
8
List the alarms on the SPM by typing
>LISTALM
and pressing the Enter key.
9
Perform the following substeps to record ENET information:
a
List the status of the ENET links by typing
>TRNSL
and pressing the Enter key.
Example of a MAP screen:
b
Record the ENET shelf number (
30
in the example above)
10
Do the following substeps to determine the MS card numbers:
a
At the CI level of MAP screen, locate the MS card that the
ENET is connected to by typing
>TABLE ENINV
and pressing the Enter key.
If the alarm list shows
Do
None
Step
MANBNA
Step
SPM 11 CEM 0 Act SysB (NA)
Loc : Row F FrPos 64 ShPos 6 ShId 0 Slot 7
Default Load: SPMLOAD
Clock:
Input Ref: Source: Current Mode:
Trnsl
Link 1: ENET 0 0 30 0; Status: OK
Link 2: ENET 1 0 30 1; Status: NA
Link 3: ENET 0 0 30 2; Status: OK
Link 4: ENET 1 0 30 3; Status: OK