Performing RAID maintenance
Standard 1.0
208
CallPilot
Use this information to select the drive that will be A-0, and then press
Enter.
Result:
The device is labeled A-0 and is the first drive for System Pack
A. The drive’s state is changed from RDY to ONL.
8
Use the tables in “RAID system pack locations and identifications” on
page 204 to identify the SCSI ID and Channel Number for hard drive A-1.
Use this information to select the drive that will be A-1, and then press
Enter.
Note:
You may be warned that you are combining two drives of different
sizes. If this happens, you must ensure that you are using CallPilot
qualified hard drives, as well as the approved version of the DAC960
Configuration & Utilities disk (see “Requirements” on page 203).
Result:
The device is labeled A-1 and is the second drive for System
Pack A. The drive’s state is changed from RDY to ONL.
9
Press Esc to close this pack.
Result:
The cursor control moves to the Pack Definition menu.
10
Repeat steps 6 to 9 for System Pack B (if applicable), and then for
System Pack C (if applicable).
Note:
There is no need to press Esc after you finish creating the last
System Pack. The last System Pack is automatically closed, and the
cursor control moves to the Pack Definition menu.
11
Select Arrange Pack, and then press Enter.
12
Select a drive from System Pack A (for example, A-0), and then press
Enter.
Result:
The System Pack is arranged.
13
Repeat step 12 for a drive in System Packs B and C (if applicable).
Result:
When all System Packs are arranged, the system returns you to
the New Configuration menu.
14
Select Define System Drive, and then press Enter.
Result:
The System Drive Definition menu appears.
Summary of Contents for CallPilot 702t
Page 2: ...P0949453 ...
Page 6: ...vi CallPilot Publication history Standard 1 0 ...
Page 26: ...Troubleshooting your CallPilot system Standard 1 0 26 CallPilot ...
Page 50: ...Using Windows NT online diagnostic tools Standard 1 0 50 CallPilot ...
Page 62: ...Using serial port diagnostic tools Standard 1 0 62 CallPilot ...
Page 76: ...Using CallPilot Manager to monitor hardware Standard 1 0 76 CallPilot ...
Page 102: ...Using CallPilot Manager to monitor hardware Standard 1 0 102 CallPilot ...
Page 194: ...Performing RAID maintenance Standard 1 0 194 CallPilot ...
Page 240: ...Performing RAID maintenance Standard 1 0 240 CallPilot ...
Page 254: ...Replacing or adding voice processing boards Standard 1 0 254 CallPilot ...
Page 264: ...Replacing DIMMs and the CPU Standard 1 0 264 CallPilot ...
Page 284: ...SSU and BIOS Standard 1 0 284 CallPilot ...
Page 304: ...Index Standard 1 0 304 CallPilot ...
Page 305: ......