Replacing a hard drive, tape drive, CD-ROM drive, or floppy drive
Standard 1.0
136
CallPilot
14
Attach power and signals cables to all drives installed in the bay. Connect
the SCSI signal cable to the wide connector on the baseboard or to the
RAID controller, as appropriate. See “SCSI and IDE cabling illustrations”
on page 126.
For proper cooling and air flow, neatly fold and secure the excess signal
cable so that the cable does not drape across the baseboard or add-in
boards. Use a tie wrap or cable clip to tie back the cable.
15
Reinstall the side cover.
16
Do one of the following steps:
a.
If this is a RAID system, then hard drives must be added in pairs.
Configure the new RAID pair as described in Chapter 9, “Performing
RAID maintenance.”
b.
If this is a non-RAID system, run the SCSI Select utility to configure
the new hard drive.
Hard drive location and SCSI ID configuration
RAID system
See “SCSI and IDE cabling illustrations” on page 126 for more information.
Location of drives in
internal drive bays
SCSI
channel
SCSI ID
System
pack label
Top slot
0
0
A-0
Second slot from top
0
1
B-0
Third slot from top
0
3
C-0
Fourth slot from top
1
4
A-1
Fifth slot from top
1
5
B-1
Sixth slot from top
(bottom slot)
1
6
C-1
Summary of Contents for CallPilot 702t
Page 2: ...P0949453 ...
Page 6: ...vi CallPilot Publication history Standard 1 0 ...
Page 26: ...Troubleshooting your CallPilot system Standard 1 0 26 CallPilot ...
Page 50: ...Using Windows NT online diagnostic tools Standard 1 0 50 CallPilot ...
Page 62: ...Using serial port diagnostic tools Standard 1 0 62 CallPilot ...
Page 76: ...Using CallPilot Manager to monitor hardware Standard 1 0 76 CallPilot ...
Page 102: ...Using CallPilot Manager to monitor hardware Standard 1 0 102 CallPilot ...
Page 194: ...Performing RAID maintenance Standard 1 0 194 CallPilot ...
Page 240: ...Performing RAID maintenance Standard 1 0 240 CallPilot ...
Page 254: ...Replacing or adding voice processing boards Standard 1 0 254 CallPilot ...
Page 264: ...Replacing DIMMs and the CPU Standard 1 0 264 CallPilot ...
Page 284: ...SSU and BIOS Standard 1 0 284 CallPilot ...
Page 304: ...Index Standard 1 0 304 CallPilot ...
Page 305: ......