![Nortel CallPilot 702t Installation And Configuration Manual Download Page 199](http://html.mh-extra.com/html/nortel/callpilot-702t/callpilot-702t_installation-and-configuration-manual_1707006199.webp)
October 2002
Performing RAID maintenance
Part 5: 702t Server Maintenance and Diagnostics
199
To rebuild a hard drive in a RAID system
1
Observe the warning message given by the DAC Monitor software that
indicates a hard drive failure.
2
Record the SCSI channel SCSI ID of the drive that failed from the
information in the DAC Monitor window.
3
Identify which drive failed using this information and referring to “RAID
system pack locations and identifications” on page 204.
4
Shut down the server, and then power down the server.
5
Remove the failed hard drive.
6
Replace with a new hard drive.
7
Power up the server.
Result:
POST messages from the RAID controller warn you that the
system is operating in critical mode (that is, with some drives offline).
8
Log on to the CallPilot server as
Administrator
(or any other user ID that
has administrative privileges).
Summary of Contents for CallPilot 702t
Page 2: ...P0949453 ...
Page 6: ...vi CallPilot Publication history Standard 1 0 ...
Page 26: ...Troubleshooting your CallPilot system Standard 1 0 26 CallPilot ...
Page 50: ...Using Windows NT online diagnostic tools Standard 1 0 50 CallPilot ...
Page 62: ...Using serial port diagnostic tools Standard 1 0 62 CallPilot ...
Page 76: ...Using CallPilot Manager to monitor hardware Standard 1 0 76 CallPilot ...
Page 102: ...Using CallPilot Manager to monitor hardware Standard 1 0 102 CallPilot ...
Page 194: ...Performing RAID maintenance Standard 1 0 194 CallPilot ...
Page 240: ...Performing RAID maintenance Standard 1 0 240 CallPilot ...
Page 254: ...Replacing or adding voice processing boards Standard 1 0 254 CallPilot ...
Page 264: ...Replacing DIMMs and the CPU Standard 1 0 264 CallPilot ...
Page 284: ...SSU and BIOS Standard 1 0 284 CallPilot ...
Page 304: ...Index Standard 1 0 304 CallPilot ...
Page 305: ......