Performing RAID maintenance
Standard 1.0
226
CallPilot
To disconnect the dead hard drives
Physically disconnect the hard drives marked DED to ensure that these hard
drives are not updated during the upgrade and are preserved as a backup.
1
Shut down and power off the CallPilot server.
2
Disconnect the hard drives marked DED by disconnecting the SCSI
cable for channel 1 from the RAID card. Be careful not to damage the
RAID card. See the cabling diagram on page 227 for the 702t server:
.
CAUTION
Risk of equipment damage and data loss
Ensure you first power off the server and use an ESD wrist
strap.
If you decide to remove the drives, be sure to label them with
their SCSI channel and ID, and store them in antistatic bags
and suitable foam material.
If you remove the drives and then label drives incorrectly (and,
therefore, are not able to reinstall the drives in the same
locations), you may not be able to recover your system using
these drives.
Summary of Contents for CallPilot 702t
Page 2: ...P0949453 ...
Page 6: ...vi CallPilot Publication history Standard 1 0 ...
Page 26: ...Troubleshooting your CallPilot system Standard 1 0 26 CallPilot ...
Page 50: ...Using Windows NT online diagnostic tools Standard 1 0 50 CallPilot ...
Page 62: ...Using serial port diagnostic tools Standard 1 0 62 CallPilot ...
Page 76: ...Using CallPilot Manager to monitor hardware Standard 1 0 76 CallPilot ...
Page 102: ...Using CallPilot Manager to monitor hardware Standard 1 0 102 CallPilot ...
Page 194: ...Performing RAID maintenance Standard 1 0 194 CallPilot ...
Page 240: ...Performing RAID maintenance Standard 1 0 240 CallPilot ...
Page 254: ...Replacing or adding voice processing boards Standard 1 0 254 CallPilot ...
Page 264: ...Replacing DIMMs and the CPU Standard 1 0 264 CallPilot ...
Page 284: ...SSU and BIOS Standard 1 0 284 CallPilot ...
Page 304: ...Index Standard 1 0 304 CallPilot ...
Page 305: ......