October 2002
Replacing or adding voice processing boards
Part 5: 702t Server Maintenance and Diagnostics
251
3
Disconnect the DS30X cable from the faceplate of the faulty MPB16-4
board.
4
Remove the faulty MPB16-4 board from its slot, and save the retaining
screw.
5
Remove any optional MPC-8 cards from the faulty MPB16-4 board, and
install the cards in the new MPB16-4 board.
Note:
If some MPC-8 cards were identified as faulty, ensure that these
are replaced with new MPC-8 cards in this step.
6
Press the new MPB16-4 board firmly into its slot.
Note:
Ensure that you carefully slide the MPB16-4 board past the
protective foil strips, as they are easily damaged.
7
Secure the board using the retaining screw that you removed earlier.
8
Reconnect the SCbus cable to the new MPB16-4 board.
Note:
If there is only one MPB16-4, the SCbus cable is not used.
9
Reconnect the DS30X cable to the faceplate of the new MPB16-4 board.
10
Replace the server cover.
Note:
Be careful not to pinch any cabling when replacing the server
cover.
11
Replace the front bezel and lock it.
12
Reconnect the peripheral devices. If you need additional instructions,
refer to Part 2 of the
CallPilot Installation and Configuration
binder.
13
Reconnect the power cables to the server and to the peripheral devices.
14
Restart the server, and then log on to Windows NT.
15
Run the Configuration Wizard to detect the new hardware.
Result:
The MPB16-4 board replacement procedure is completed.
16
Test the multimedia channels to ensure the new MPB16-4 board is
functioning properly.
Refer to “Testing the CallPilot installation” in Part 3 of the
CallPilot
Installation and Configuration
binder.
Summary of Contents for CallPilot 702t
Page 2: ...P0949453 ...
Page 6: ...vi CallPilot Publication history Standard 1 0 ...
Page 26: ...Troubleshooting your CallPilot system Standard 1 0 26 CallPilot ...
Page 50: ...Using Windows NT online diagnostic tools Standard 1 0 50 CallPilot ...
Page 62: ...Using serial port diagnostic tools Standard 1 0 62 CallPilot ...
Page 76: ...Using CallPilot Manager to monitor hardware Standard 1 0 76 CallPilot ...
Page 102: ...Using CallPilot Manager to monitor hardware Standard 1 0 102 CallPilot ...
Page 194: ...Performing RAID maintenance Standard 1 0 194 CallPilot ...
Page 240: ...Performing RAID maintenance Standard 1 0 240 CallPilot ...
Page 254: ...Replacing or adding voice processing boards Standard 1 0 254 CallPilot ...
Page 264: ...Replacing DIMMs and the CPU Standard 1 0 264 CallPilot ...
Page 284: ...SSU and BIOS Standard 1 0 284 CallPilot ...
Page 304: ...Index Standard 1 0 304 CallPilot ...
Page 305: ......