Performing RAID maintenance
Standard 1.0
210
CallPilot
3
Use the arrow keys to navigate to a system drive. Press Enter to select
the drive. Repeat this step for each system drive.
Result:
A check mark indicates a selected drive.
4
Press Esc.
Result:
The Initialize System Drive menu appears.
5
Select
Start Initialize, and then press Enter.
Result:
The system prompts you to confirm that you want to initialize this
system drive.
6
Select Yes, and then press Enter.
Result:
The system drives are initialized. This takes from 1 to 5 hours,
depending on the size of the hard drives and the number of hard drives.
All system drives are initialized simultaneously.
When the initialization is complete, the system prompts you to press any
key to continue.
7
Press any key to continue.
Result:
The configuration is saved.
8
Continue with “To back up the RAID configuration” below.
To back up the RAID configuration
1
Select Tools from the DAC960 Configuration Utility main menu, and then
press Enter to display the Tools menu.
2
Select Backup/Restore conf, and then press Enter.
Result:
A cautionary message appears.
3
Press any key to acknowledge the cautionary message.
Result:
The system displays the Backup and Restore Configuration
submenu.
4
Select Backup Configuration, and then press Enter.
Result:
The system displays the Enter File Name pop-up window.
Summary of Contents for CallPilot 702t
Page 2: ...P0949453 ...
Page 6: ...vi CallPilot Publication history Standard 1 0 ...
Page 26: ...Troubleshooting your CallPilot system Standard 1 0 26 CallPilot ...
Page 50: ...Using Windows NT online diagnostic tools Standard 1 0 50 CallPilot ...
Page 62: ...Using serial port diagnostic tools Standard 1 0 62 CallPilot ...
Page 76: ...Using CallPilot Manager to monitor hardware Standard 1 0 76 CallPilot ...
Page 102: ...Using CallPilot Manager to monitor hardware Standard 1 0 102 CallPilot ...
Page 194: ...Performing RAID maintenance Standard 1 0 194 CallPilot ...
Page 240: ...Performing RAID maintenance Standard 1 0 240 CallPilot ...
Page 254: ...Replacing or adding voice processing boards Standard 1 0 254 CallPilot ...
Page 264: ...Replacing DIMMs and the CPU Standard 1 0 264 CallPilot ...
Page 284: ...SSU and BIOS Standard 1 0 284 CallPilot ...
Page 304: ...Index Standard 1 0 304 CallPilot ...
Page 305: ......