Performing RAID maintenance
Part 5: 702t Server Maintenance and Diagnostics
217
3
From the DAC Administration Utility window, select Configuration
➝
System Drive Information.
Result:
The System Drive Information dialog box appears.
4
Check that all system drives are in the online state.
If any system drives are not online, go to the procedure in
“Resynchronizing the CallPilot server hard drives” on page 229, and
follow steps 6 to 8 to rebuild any hard drives that are not online. Then
return to this procedure.
Note:
If a hard drive does not successfully go to the online state, verify
the hard drive jumper settings and cabling connections, and then try
again to rebuild the hard drive. If you cannot make the hard drive go to
the online state, replace the faulty hard drive (see “Replacing or installing
hard drives” on page 131 for hard drive configuration instructions and, if
necessary, instructions on how to replace the hard drive).
5
Click OK to exit from the System Drive Information dialog box.
Summary of Contents for CallPilot 702t
Page 2: ...P0949453 ...
Page 6: ...vi CallPilot Publication history Standard 1 0 ...
Page 26: ...Troubleshooting your CallPilot system Standard 1 0 26 CallPilot ...
Page 50: ...Using Windows NT online diagnostic tools Standard 1 0 50 CallPilot ...
Page 62: ...Using serial port diagnostic tools Standard 1 0 62 CallPilot ...
Page 76: ...Using CallPilot Manager to monitor hardware Standard 1 0 76 CallPilot ...
Page 102: ...Using CallPilot Manager to monitor hardware Standard 1 0 102 CallPilot ...
Page 194: ...Performing RAID maintenance Standard 1 0 194 CallPilot ...
Page 240: ...Performing RAID maintenance Standard 1 0 240 CallPilot ...
Page 254: ...Replacing or adding voice processing boards Standard 1 0 254 CallPilot ...
Page 264: ...Replacing DIMMs and the CPU Standard 1 0 264 CallPilot ...
Page 284: ...SSU and BIOS Standard 1 0 284 CallPilot ...
Page 304: ...Index Standard 1 0 304 CallPilot ...
Page 305: ......