Performing RAID maintenance
Standard 1.0
188
CallPilot
Reverting to the pre-upgrade system (if the upgrade fails)
This section describes how to restore the CallPilot server to the state it was
in before you began the upgrade. This procedure includes the following
steps:
1. Disconnect the failed upgrade hard drives.
2. Clear the current RAID configuration.
3. Reconnect the pre-upgrade hard drives.
4. Enable the pre-upgrade hard drives.
5. Verify that the pre-upgrade hard drives are functioning properly.
6. Reconnect the failed upgrade hard drives.
7. Resynchronize the hard drives to finish restoring the pre-upgrade system.
To disconnect the failed upgrade hard drives
1
Ensure that you have powered off the CallPilot server.
2
Disconnect the failed upgrade hard drives by labeling and then
disconnecting the SCSI cable for channel 0. For cabling details, see the
diagram in “To disconnect the secondary hard drives” on page 180.
.
CAUTION
Risk of lost or corrupted data
Ensure that all hard drives are disconnected before you
continue with the rest of this procedure.
Summary of Contents for CallPilot 702t
Page 2: ...P0949453 ...
Page 6: ...vi CallPilot Publication history Standard 1 0 ...
Page 26: ...Troubleshooting your CallPilot system Standard 1 0 26 CallPilot ...
Page 50: ...Using Windows NT online diagnostic tools Standard 1 0 50 CallPilot ...
Page 62: ...Using serial port diagnostic tools Standard 1 0 62 CallPilot ...
Page 76: ...Using CallPilot Manager to monitor hardware Standard 1 0 76 CallPilot ...
Page 102: ...Using CallPilot Manager to monitor hardware Standard 1 0 102 CallPilot ...
Page 194: ...Performing RAID maintenance Standard 1 0 194 CallPilot ...
Page 240: ...Performing RAID maintenance Standard 1 0 240 CallPilot ...
Page 254: ...Replacing or adding voice processing boards Standard 1 0 254 CallPilot ...
Page 264: ...Replacing DIMMs and the CPU Standard 1 0 264 CallPilot ...
Page 284: ...SSU and BIOS Standard 1 0 284 CallPilot ...
Page 304: ...Index Standard 1 0 304 CallPilot ...
Page 305: ......