Operation
4‐28
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Control Panel of the Industrial PC (IPC)
Heatup phase
Melter Modes ‐ Overview ‐
⇒
Control mode
Standard
or
Field bus / Field bus (extended)
or
Dual / Dual (extended)
⇒
Speed control
Manual mode
Key‐to‐line
⇒
Pressure control
Manual mode
Key‐to‐line
Option
Field bus communication
: Beginning with the software version
V5.02.004, there are two additional control modes available,
Field
bus (extended)
and
Dual (extended)
. The corresponding screen on the
control panel has been modified (Fig. 4‐20).
Standard
Field bus
Dual
Profibus address
10
Control mode
Profibus address
10
Control
panel
Standard I/O
No Profibus
< V5.02.004
≥ V5.02.004
Example, option Profibus, selected control mode
Standard
Summary of Contents for VersaBlue VA
Page 12: ...Table of Contents X P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 28: ...Safety Instructions 1 14 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 40: ...Introduction 2 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 62: ...Installation 3 22 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 74: ...Operation 4 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 142: ...Operation 4 80 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 174: ...Maintenance 5 26 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 204: ...Troubleshooting 6 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 234: ...Repair 7 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 248: ...Password A 4 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 272: ...Glossary D 16 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...