Overtemperature shutdown
Standby value
° C
Overtemperature warning
Undertemperature warning
Undertemperature fault
50
5
10
Grid
° C
5
° C
° C
° C
20
° C
Overtemperature fault
10
T2
Operation
4‐32
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Temperature Parameters
(contd.)
Grid
Parameters (Screen 1: Alarm Values)
NOTE:
The temperatures in this screen are differential values.
Standby temperature
=
Setpoint temperature -
Standby value
The minimum standby temperature is 40 °C (100 °F), even if the selected
settings would (mathematically) permit the standby temperature to be lower.
Standby value:
50 °C
(90 °F)
The
values*
are not a factor of the setpoint during the heatup and cooling
phases (Refer to
Monitoring of Heatup and Cooling
).
When the ALL, ALL HOSES and ALL GUNS groups are used, the values for
warning and fault are always assumed together, even if only one of the
values has been changed. This ensures that the fault value is always larger
than or equal to the value for the respective warning.
Warning
Overtemperature
=
Setpoint tempe
Overtemperature warning
delta*
Warning
Undertemperature
=
Setpoint temperature -
Undertemperature
warning delta*
NOTE:
The warning value is a factor of the fault value in that the values for
the warning may not be larger than the corresponding values for the faults.
When appropriate, first increase the fault value.
Overtemperature/undertemperature warning:
5 °C
(10 °F)
Fault
Overtemperature
=
Setpoint tempe
Overtemperature fault
delta*
Fault
Undertemperature
=
Setpoint temperature -
Undertemperature fault
delta*
Overtemperature/undertemperature fault:
10 °C
(18 °F)
Summary of Contents for VersaBlue VA
Page 12: ...Table of Contents X P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 28: ...Safety Instructions 1 14 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 40: ...Introduction 2 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 62: ...Installation 3 22 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 74: ...Operation 4 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 142: ...Operation 4 80 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 174: ...Maintenance 5 26 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 204: ...Troubleshooting 6 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 234: ...Repair 7 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 248: ...Password A 4 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 272: ...Glossary D 16 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...