Melter configuration
Melter
Fig. 4‐83
V26 - Overview -
Melter configuration
Select pressure build‐up or pressure
control for each pump
Field bus data protocol:
Standard
7
Melter configuration
PUMP 1
PUMP 2
Pressure
build‐up
feature
Pressure
build‐up
feature
Fig. 4‐85
V28
Pressure sensors
New sensor
Fig. 4‐86
V22 - Overview -
Operation
4‐64
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Melter
(contd.)
Melter Configuration
If the memory board is replaced or parts relevant to the configuration are
retrofitted, the melter software configuration code must be entered twice.
Touch
next to the configuration code.
NOTE:
The options are shown in the configuration code following the slash.
If no options or no additional options are entered, the software automatically
places an X in the remaining positions.
If the two codes entered are the same, the key to confirm is enabled. After
confirmation, the system returns to the overview screen.
NOTE:
All of the configurations are saved on the memory board only when
the key
Confirm
is touched in the overview screen.
Selecting the Type of Field Bus Data Protocol
Refer to
Standard Index Protocol
or
Extended Index Protocol
in the separate
field bus documentation.
CAUTION:
The type of protocol selected on the control panel must
correspond to the implementation on the master; the type may not be
changed during field bus operation.
Select pressure build‐up
or
Pressure control for each pump
. The parameters
are set in in the screens
Motor
.
Depending on what is selected in screen V28, speed control / pressure
control or speed control / pressure build‐up feature can be selected in the
motor screen M5.
Pressure sensor setup
A CAN bus sensor is found automatically and indicated by the lamp.
Continue with
to assign the pressure sensor to a pump (example).
NOTE:
Only one pressure sensor can be assigned at a time.
Summary of Contents for VersaBlue VA
Page 12: ...Table of Contents X P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 28: ...Safety Instructions 1 14 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 40: ...Introduction 2 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 62: ...Installation 3 22 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 74: ...Operation 4 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 142: ...Operation 4 80 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 174: ...Maintenance 5 26 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 204: ...Troubleshooting 6 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 234: ...Repair 7 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 248: ...Password A 4 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 272: ...Glossary D 16 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...