Troubleshooting
6‐13
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Level (Fixed Measuring Points - 5‐point Sensor)
Warning Tank Overfilled
If the measuring point
Tank overfilled
is reached or exceeded for longer than
5 seconds, a warning is triggered.
Automatic Reset
When the level falls below the measuring point.
Warning Tank Level Low
When the level falls below the measuring point
Tank level low
for longer than
five seconds, a warning is triggered.
Automatic Reset
When the measuring point is reached.
Fault Tank Empty
When the level falls below the measuring point
Tank empty
for longer than
five seconds, a fault is triggered.
Automatic Reset
When the measuring point is reached.
Fault Level Sensor Defective
The level sensor transmits a faulty signal for longer than five seconds.
Fault Level Sensor Failure
Triggered when a wire breaks.
Automatic Reset
After replacement of the defective sensor.
Summary of Contents for VersaBlue VA
Page 12: ...Table of Contents X P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 28: ...Safety Instructions 1 14 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 40: ...Introduction 2 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 62: ...Installation 3 22 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 74: ...Operation 4 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 142: ...Operation 4 80 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 174: ...Maintenance 5 26 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 204: ...Troubleshooting 6 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 234: ...Repair 7 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 248: ...Password A 4 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 272: ...Glossary D 16 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...