Troubleshooting
6‐25
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
LEDs of Temperature Control Board
D13
D14
D8
D6
D2
D5
D4
D3
D1
D7
LED
D7
Operating voltage present
D8
CAN data received or transmitted
D14
No connection to control unit (IPC)
D13
Lit: Controller software reset
Flashing: CAN fault counter overflow, stack error, power
down not finished properly
D1
Heater output of the first channel is switched on.
NOTE:
Depending on position of dials S1 and S2, the first
channel of this temperature control board is channel 1, 7 or
13.
D2 (... D6)
Heater output of the second channel (... the sixth channel) is
switched on.
Summary of Contents for VersaBlue VA
Page 12: ...Table of Contents X P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 28: ...Safety Instructions 1 14 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 40: ...Introduction 2 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 62: ...Installation 3 22 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 74: ...Operation 4 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 142: ...Operation 4 80 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 174: ...Maintenance 5 26 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 204: ...Troubleshooting 6 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 234: ...Repair 7 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 248: ...Password A 4 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 272: ...Glossary D 16 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...