Control Panel P/N 207023 and P/N 207850 (First Generation)
B‐3
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Control Panel does not Function
1
+5V LED
1)
LINK LED
2)
ACT LED
3)
Problem
Possible cause
Corrective action
1.
Does not start.
Control panel dark or
fault indications upon
startup
Fuse (1) defective (+5V LED
1)
not
lit)
Check voltage supply
Memory board (CompactFlash) not
in place
Insert as described in section
Replacing Memory Board
2.
Date/time incorrect
Insert or replace battery and set date
and time
3.
Control panel dark or
bright
Background lighting / contrast
misadjusted
Use
to adjust
4.
Control Panel does
not Function
Hardware defective
Control panel dirty *)
Clean as described in section
Maintenance / External Cleaning /
Control Panel
5.
No EtherNet
connection
Wrong/invalid IPC IP address set
Correct the IP address on the control
panel
Refer to the section
Operation, Operation
via the IPC Webserver
Incorrect EtherNet cable plugged in
The LINK LED
2)
is lit when connected
properly
The ACT LED
3)
is lit when data is
transferred properly (flashes during
transmission)
Missing/defective cables or
components
Check connecting cable between
IPC, EtherNet switch and
coprocessor. Connect as shown in
the system plan, if necessary.
*) The software checks the surface of the control panel during startup and
indicates dirt or defects with an X. Fingers or notepaper would also be
recognized as a "fault," stopping initialization until the fault is remedied.
Summary of Contents for VersaBlue VA
Page 12: ...Table of Contents X P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 28: ...Safety Instructions 1 14 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 40: ...Introduction 2 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 62: ...Installation 3 22 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 74: ...Operation 4 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 142: ...Operation 4 80 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 174: ...Maintenance 5 26 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 204: ...Troubleshooting 6 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 234: ...Repair 7 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 248: ...Password A 4 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 272: ...Glossary D 16 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...