Fig. 7‐28
V025
Repair
7‐19
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Replacing Heater Connection Insulation
ATTENTION:
The melter may not be operated without properly insulated
heater connections. Use only Nordson spare parts for insulation.
The heater connection insulation may be damaged when maintenance and
repair work is performed.
1. Remove nut (4), washers (3 and 5) and insulating cylinder (2).
2. Remove all of the ceramic powder from the heater connection.
3. Guide new insulating cylinder (1) into the heater connection.
4. Attach new insulating cylinder (2), washer (3) and nut (4). Carefully
tighten the nut with 1 Nm (8.85 lbin).
5. Attach heater cable, spring washer (5) and nut (4). Brace the first nut with
a tool to prevent damage to the insulating cylinder and tighten the second
nut with 3 Nm (27 lbin).
5
4
3
2
1
4
3 Nm
1 Nm
1 Insulating cylinder, small
2 Insulating cylinder, large
3 Washer
4 Hexagonal
nut
5 Spring
washer
Summary of Contents for VersaBlue VA
Page 12: ...Table of Contents X P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 28: ...Safety Instructions 1 14 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 40: ...Introduction 2 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 62: ...Installation 3 22 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 74: ...Operation 4 12 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 142: ...Operation 4 80 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 174: ...Maintenance 5 26 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 204: ...Troubleshooting 6 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 234: ...Repair 7 30 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 248: ...Password A 4 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...
Page 272: ...Glossary D 16 P N 213828_11 2014 Nordson Corporation VersaBlue_PPA...