No
.
LCD Display
Contents
Method to Recover
80
Unsupported SCSI
Command Er-
Ad
A SCSI Command from
PC
is not supported.
(
1
)
Check whether the
transmitted SCSI
Command is listed in the
Command Specification.
(
2
)
Clear the error by pressing
the CLEAR key and
send the command again.
81
Parameter List
Length Err Er- Ad
Group Code of the
SCSI command does not
meet with the
specification or actually
transmitted byte
does not match the set
byte number.
(
1
)
Check the group code of
the sent SCSI command
and
transfer byte number of
the command description
block.
(
2
)
Clear the error by pressing
CLEAR key and send
the command again.
82
Invalid Field
in CDB. Er- Ad
There is error in the
description block of
the received SCSI
command
(
1
)
Check if the command
description block meets
the contents of the
Command Specification.
(
2
)
Clear the error by pressing
the CLEAR key and
send the command again.
83
Logical Unit Not
Supported Er-Ad
LUN of the received
SCSI command is not
zero.
(
1
)
Check whether the LUN
of the command descript-
ion block is zero or not.
(
2
)
Press CLEAR key to clear
the error and send the
command again.
85
SCSI Parity
Error Er - Ad
Parity error has
occurred while
communicating through
SCSI interface.
(
1
)
Turn OFF the power and
check the command and
data. Check whether the
SCSI controller of the
host supports the parity
adding function. If not
supporting, select
"Parity OFF" on the
Operation Panel and
communicate.
(
2
)
If the error repeats,
replace the following.
PBA-IF