(7)
Hardware damage
Service Man Call
Error Code **
Er Ad
Symptom
Check/Repair
30 ** No s ignal fed back from
the
sensor 6, when F.Turn unit
rotating.
(
1
)
Open the top cover and check if there is
an obstacle such as a card.
(
2
)
If there is a card protruding from the flip
turn unit and hitting the sensor etc.,
card transport accuracy defect is
doubted. Remove the staying card and
clean the transport rollers in the flip
turn unit.
(
3
)
If there is no obstacle, check the out put
on SN6 in Sensor Check Mode
When abnormal situation is found, go
(*b)
(
4a
)
PM1 is doubted. Check the motion of
PM1 in the Actuator Check Mode.
(
5a
)
If PM1 does not work, check connection
and electrical contact of the harness.
·
ASM-MOTOR
(
6a
)
If the harness connection is normal,
replace the following:
·
PM1
·
PBA- MAIN
(
4b
)
Turn angle sensors are doubted.
Check connection and electrical contact
of the harness.
·
ASM-SENSOR-A
(
5b
)
If the harness connection is normal,
replace the following:
·
SN6
·
PBA- MAIN
31
02
03
04
F.Turn unit stops the
position where is before
target position
F.Turn unit stops the
position where is after
target position
F.Turn unit stops the
position where is not in
detection range.
(
1
)
Open the top cover and check if there is
an obstacle such as a card.
(
2
)
If there is a card protruding from the flip
turn unit and hitting the sensor etc.,
card transport accuracy defect is
doubted. Remove the staying card and
clean the transport rollers in the flip
turn unit.
(
3
)
If there is no obstacle, check the out put
on SN6 in Sensor Check Mode
When abnormal situation is found, go
(*b)
Er
Ad
Symptom
Check/Repair