(4a) Re-adjust the stop position of F.Turn unit.
*Home angle Adj.
*Pickup angle Adj.
(
4b
)
Turn angle sensor (SN7) is doubted.
Check connection and electrical contact
of the harness.
·
ASM-SENSOR-A
(
5b
)
If the harness connection is normal,
replace the following:
·
SN7
·
PBA- MAIN
32
**
Head is not detected in the
specified position within
the
specified time when the
head
lifting motor is activated.
(
1
)
Check the motion of DM3 in the Actuator
Check Mode. If the motor works
normally, go to
(
2b
)
.
(
2a
)
DM1 is doubted. Check connection
and electrical contact of the harness.
·
ASM-MOTOR
(
3a
)
If the harness connection is normal,
replace the following:
·
DM1
·
PBA-MAIN
(
2b
)
The head position sensors seem to have
problem.
(
SN11, SN12
)
Check connection and electrical contact
of the harnesses.
·
ASM-SENSOR-C
(
3b
)
If the harness connection is normal,
replace the following:
·
SN11
·
SN12
·
PBA-MAIN
36
01
|
06
Impossible to adjust
ribbon leading edge
sensor
properly.
(
1
)
Check connection and electrical contact
of the harnesses.
·
ASM-SENSOR- B
·
ASM-LD RELAY 2
(
2
)
If the harness connection is normal,
replace the following:
·
SN10
(
LD/PT
)
·
PBA-MAIN
Er Ad
Symptom
Check/Repair