(Heat Roller Check)
To adjust a Heat Roller unit
*Display the total heating time
Heat Total Time : heater total power on time
Clear key : N/A
Exe key : N/A
*To adjust transferring position
Position Adj. : adjusting transferring position (horizontal direction)
unit of adjustment= 0.2mm
Clear key : decrement value (min.-10)
Exe key : increment value (max.+10)
*Sensor adjustment
Sensor Adj : auto adjustment of ribbon detection sensor
Clear key : N/A
Exe key : execute auto adjustment
-
+
Card
Hologram
Note : Execute this adjustment after taking ribbon cassette out.
Note : Must execute this menu when replace sensor and main board.