294
07
|
Trouble shooting
Reset
Reset function is a procedural function for returning the robot status from abnormal to normal.
Reset is carried out only in abnormal state and it is executed by pressing
Reset
located on the
right side of the top menu. This reset function is performed by selecting automatically one of the
following two methods according to the alarm type.
Soft reset
After five to ten seconds around without any change, the robot state will be restored to
normal state by software reset.
Hard reset
The motor power and the endtool indicator are turned off and restarted while the
control box power remains on. It may take about two to three minutes. As the endtool
indicator flashes red, the motor power is sequentially supplied and the brakes are
released at the same time and the motor is restored to the normal state.
Summary of Contents for INDY7
Page 1: ...Version 2 3 0 2019 08 16...
Page 2: ......
Page 3: ......
Page 5: ...5...
Page 8: ......
Page 12: ......
Page 15: ......
Page 128: ...128 05 Programming Now your jointMove setup is complete...
Page 144: ...144 05 Programming Now the setting for the blending of frameMove is completed...
Page 152: ...152 05 Programming Now your home movement setup is complete...
Page 162: ...162 05 Programming stop It stops program execution No setup is required...
Page 257: ...257 The commands that can be executed by the digital input signals are listed as follows...
Page 279: ...279 If you run Conty again the language is changed and shown as follows...
Page 321: ...321 09 Certification 9 Certification 9 1 Machinery Directive...
Page 322: ...322 09 Certification 9 2 Electromagnetic Compatibility Directive...