Maintenance and Repair
8.4
Periodic Inspection
In periodic inspection, inspections are made for the items that cannot be inspected during
operation or requires a lot of time to check, and it should be made even when the operational
state is good. Periodic inspection is mainly focused on cleaning parts and visual inspection of the
components, but some items require specialized knowledge. In case you need such inspections,
please contact the manufacturer.
Inspection Interval
Once per six months or year
Inspection Method
Robot arm
Check the interior state as well as the exterior appearance of the robot. As disassembling
the robot arm for some parts is required, consult with the manufacturer.
Inspection item
Inspection method
interior
After disassembling the joint cover, check the tightness of screws.
Measure the encoder battery voltage after disassembling the joint
cover. Replacement is required if the voltage is less than 3.2V.
function
Check whether the functions provided by Conty are all working well.
Make sure that the robot is moving exactly to the position you specified
and that there is no vibration during movement.
Control box
If dust accumulates inside the control box, overheating due to non-smooth air circulation
or static electricity may cause the product to malfunction or fail. Therefore, check the
inside of the control box and the air circulation system to remove dust. Also, make sure
that the cables connected inside are properly connected. When checking the control
box, be sure to turn off the power and disconnect the power cable completely from the
power socket before proceeding.
Inspection item
Inspection method
interior cleaning
Make sure that there is no dust accumulated inside, and use a vacuum
cleaner to remove the dust carefully.
filter cleaning
Make sure that dust is not accumulated on the filter, and use a vacuum
cleaner to remove the dust carefully.
filter replacement
Check the filter for damage.
Check the period of use. For the replacement cycle, refer to
Section 8.6
Parts Replacement Cycle
.
input voltage
measurement
Use a multimeter to measure the power supplied from the power
distribution board. The normal range is within 100 to 240 VAC.
insulation resistance
measurement
Refer to
Section 8.5 How to Measure Insulation Resistance
.
Summary of Contents for INDY7
Page 1: ...Version 2 3 0 2019 08 16...
Page 2: ......
Page 3: ......
Page 5: ...5...
Page 8: ......
Page 12: ......
Page 15: ......
Page 128: ...128 05 Programming Now your jointMove setup is complete...
Page 144: ...144 05 Programming Now the setting for the blending of frameMove is completed...
Page 152: ...152 05 Programming Now your home movement setup is complete...
Page 162: ...162 05 Programming stop It stops program execution No setup is required...
Page 257: ...257 The commands that can be executed by the digital input signals are listed as follows...
Page 279: ...279 If you run Conty again the language is changed and shown as follows...
Page 321: ...321 09 Certification 9 Certification 9 1 Machinery Directive...
Page 322: ...322 09 Certification 9 2 Electromagnetic Compatibility Directive...