304
08
|
Maintenance and Repair
8.2
Routine Inspection
Routine inspections usually consist of visual and auditory inspections to check any change from
normal states.
Inspection Interval
Routinary
Inspection Method
Environment
Check for variations in dust, gas, rain, room temperature, humidity, etc.
Inspection item
Inspection method
dust, water, other liquids Check whether there is dust and water around.
gas
Check whether you smell something different than usual.
temperature, humidity
Use a thermometer and a hygrometer to check the
ambient temperature and humidity.
Appropriate temperature is within 0 to 40 ℃.
Robot arm
Inspection item
Inspection method
vibration, noise
While repeating some motions, check whether noise or
vibration occurs in the motor or the reducer.
abnormal heat
Check if high temperature of 80 °
C or more occurs
around the motor.
abnormal movement
After moving the robot to the zero position, check
whether the zero tick at each joint to see if they are
aligned.
Check whether the robot arm or tool falls excessively
down when the power is turned off.
Summary of Contents for INDY7
Page 1: ...Version 2 3 0 2019 08 16...
Page 2: ......
Page 3: ......
Page 5: ...5...
Page 8: ......
Page 12: ......
Page 15: ......
Page 128: ...128 05 Programming Now your jointMove setup is complete...
Page 144: ...144 05 Programming Now the setting for the blending of frameMove is completed...
Page 152: ...152 05 Programming Now your home movement setup is complete...
Page 162: ...162 05 Programming stop It stops program execution No setup is required...
Page 257: ...257 The commands that can be executed by the digital input signals are listed as follows...
Page 279: ...279 If you run Conty again the language is changed and shown as follows...
Page 321: ...321 09 Certification 9 Certification 9 1 Machinery Directive...
Page 322: ...322 09 Certification 9 2 Electromagnetic Compatibility Directive...