Removal Procedure
Remove the 8G FC Switch from a Blade Enclosure (SIGMABLADE) according to the procedure
described below.
CAUTION
Avoid installation in extreme temperature conditions.
1.
Remove the fibre channel cable connected to the 8G FC Switch.
IMPORTANT:
Remove the fibre channel cable with close attention. Removing the fibre channel cable
with excess force may cause the mating connector on the fibre channel cable to be
damaged or the cable to be disconnected.
Always put caps on the connectors of the removed fibre channel cable. If a fibre
channel cable is left without caps put on the connectors, a fault may occur in its reuse
due to dust adhering on the connectors.
2.
Remove the SFP+ module installed on the 8G FC Switch.
IMPORTANT:
See Section 4-2 for the SFP+ module removal procedure.
Always put dust covers on the removed the SFP+ module. If the SFP+ module is left
without dust cover, a fault may occur on its reuse due to dust adhering on the module.
3.
Unlock the stopper on the 8G FC Switch to unlatch the ejector.
NOTE:
Press the stopper lightly in the right direction to unlock the stopper. Then the
ejector is unlatched.
4.
Pull out the ejector toward you lightly.
Immediately after the 8G FC Switch is powered off, its internal
components and components in Blade Enclosure are very hot. Leave
them until their internal components fully cool down before
installing/removing any component.