Fill Word 0 0 0 0 0 0 0 0
AL_PA Offset 13 .. .. .. .. .. .. .. ..
Trunk Port ON ON ON ON ON ON ON ON
Long Distance .. .. .. .. .. .. .. ..
VC Link Init .. .. .. .. .. .. .. ..
Locked L_Port .. .. .. .. .. .. .. ..
Locked G_Port .. ON ON ON ON ON ON ON
Disabled E_Port .. .. .. .. .. .. .. ..
ISL R_RDY Mode .. .. .. .. .. .. .. ..
RSCN Suppressed .. .. .. .. .. .. .. ..
Persistent DisableON .. .. .. .. .. .. ..
NPIV capability ON ON ON ON ON ON ON ON
QOS E_Port AE AE AE AE AE AE AE AE
Mirror Port .. .. .. .. .. .. .. ..
Rate Limit .. .. .. .. .. .. .. ..
Credit Recovery ON ON ON ON ON ON ON ON
Fport Buffers .. .. .. .. .. .. .. ..
Port Auto Disable .. .. .. .. .. .. .. ..
where AE:QoSAutoEnable, AN:AutoNegotiate, ..:OFF, NA:NotApplicable, ??:INVALID,
LM:L0.5
ALE044120T2:admin>
IMPORTANT:
The port status display also includes the information on the ports unavailable to
N8406-040. However, this is not an error.
3.
Change the port topologies.
Type "portcfggport x y" to change the topology of a port.
Value "x" is the number of the port whose topology is to be changed.
External ports available to N8406-040: 17 - 20
External ports available to N8406-042: 17 - 23 and 0
Value "y" shows whether fixing the port topology to be set is enabled or disabled.
0 = Disable or 1 = Enable
ALE044120T2:admin> portcfggport 17 1
ALE044120T2:admin>
NOTE:
The topology of a specific port in an 8G FC Switch can be changed individually.
IMPORTANT:
The topologies of internal ports cannot be fixed.
Any port for which the setting is made enabled cannot accept the connection of a loop
device.
Always specify "Enable" if devices are connected with which port mode is fabric
(point-to-point). If "disable" is selected, some connected devices may not be
recognized.
When cascading connection is made between the 8G FC Switch, the ports used for
cascading path must be set “Enabled”.
4.
After the setting is changed completely, type "portcfgshow" command.
Check if the new setting resulting from the change is made effective. The setting is completed if the
information on each changed port appears as shown below.