(1) ON/OFF Conditions of LEDs
The following describes the ON/OFF conditions of LEDs on the 8G FC Switch.
Check the ON/OFF status of each LED to take required action.
ID LED
LED status
Condition
Required action
Illuminating in blue or OFF
Normal
–
IMPORTANT:
If the ID LED does not illuminate in blue or is not OFF after passage for three minutes
or longer from power-on, a fault may occur in the 8G FC Switch. Contact your service
representative.
Status LED
LED status
Condition
Required action
Illuminating in green
Normal
–
Check the interface connectivity
between CPU Blade and the 8G
FC Switch.
Interface mismach may occur.
Blinking in amber
IMPORTANT:
If the status LED does not illuminate in green after passage for three minutes or longer
from power-on, a fault may occur in the 8G FC Switch. Contact your service
representative.
ACT LED
LED status
Condition
Required action
Illuminating in green
Normal
–
Check if the power of the 8G FC
Switch is set to ON and the 8G FC
Switch is started normally if set to
ON.
Starting the 8G FC Switch is not
completed yet or an error occurs
in start of the 8G FC Switch.
OFF
A device error such as a
temperature error may occur.
Check if fans in Blade Enclosure
work normally.
Check if the ambient temperature
of installation location satisfies the
operation uarantee condition.
Blinking in green
slowly
(1-sec interval)
One or more port is diagnostic
error.
Check port status LEDs.
Starting the 8G FC Switch is not
completed yet.
Wait for three minites or longer.
Illuminating in amber
One or more port is in the offline
status.
Check the port status LED.
- 125 -