4-1. Installing/Removing the 8G FC Switch
Installation Procedure
Install the 8G FC Switch in a Blade Enclosure (SIGMABLADE) according to the procedure
described below.
IMPORTANT:
Note the following when the 8G FC Switch is installed in a Blade Enclosure
(SIGMABLADE). If more than one 8G FC Switch are installed in a Blade Enclosure
(SIGMABLADE), install them one by one. After the previous 8G FC Switch is started,
install the next one. Installing more than one 8G FC Switch in a Blade Enclosure
(SIGMABLADE) simultaneously may cause linkup errors to occur at the respective
internal ports.
CAUTION
Install the 8G FC Switch in a Blade Enclosure (SIGMABLADE)
ecurely.
1.
Check the switch module slot on the Blade Enclosure (SIGMABLADE) into which the 8G FC Switch
is inserted.
The figure below shows the switch module slots into which the 8G FC Switch can be installed on
each type of Blade Enclosures (SIGMABLADE).
Slot 5
Slot 3
Slot 1
SIGMABLADE-M
Slots in which 8G FC Switch can be installed
SIGMABLADE-M (slot numbers 3 - 6)
SIGMABLADE-H
(slot numbers 3 - 8)
SIGMABLADE-H
Slot 6
Slot 4
Slot 2
Slot 1
Slot 3
Slot 5
Slot 7
Slot 2
Slot 4
Slot 6
Slot 8
NOTE:
For details of switch module slots into which the 8G FC Switch can be inserted,
refer to the User’s Guide attached to the Blade Enclosure (SIGMABLADE) to be
used.
The 8G FC Switch can be installed in a Blade Enclosure (SIGMABLADE) if the
Enclosure is operated. For the notes on the installation, refer to the User’s Guide
attached to the Blade Enclosure (SIGMABLADE).
s
Install the 8G FC Switch in a Blade Enclosure (SIGMABLADE) securely.
Loose installation may cause poor contact to lead smoke and/or fire.
- 131 -