ALE044120T2:admin>
7.
After making connected 8G FC Switch effective, execute the "switchShow" command for each 8G
NOTE:
FC Switch to check connections among the 8G FC Switch.
If the casca e path can be linked normally, the status message on each connected port
)
cted between specific 8G FC Switch,
d
is either of the following ones:
E-Port WWN "Switch Name" (upstream)
E-Port WWN "Switch Name" (downstream
If more than one cascade path are conne
"(upstream)" and "(downstream)" do not appear for the second and following cascade
paths.
If a status message other than above appears, a malfunction is detected in the
cascade connection. Retry the job from the beginning.
Sample display: Domain ID overlap
Online E-Port segmented,(domain overlap)
IMPORTANT:
Before cascade connection can be provided for 8G FC Switch, the zoning setting of the
8G FC Switch should always be deleted. Cascade connection under zoning status may
cause an error to occur.
Any 8G FC Switch with a duplicate domain ID cannot be subjected to cascade
connection. Always change the domain IDs of 8G FC Switch subjected to cascade
connection to be unique.
The data transmission speed between 8G FC Switch subjected to cascade connection
is 8G bps per path.
For cascade connection, first check the upper limit of the data transmission speed
between 8G FC Switch.
1
AN No_Sync FC Disabled (Persistent)
16 16 011000 cu AN No_Sync FC
-Port 10:00:00:05:1e:8d:74:44 "ALM0608E03E" (upstream)
-Port 2a:00:01:23:45:67:89:01
ALE044120T2:admin>switchshow
↓
(
Omitted
)
5 15 010f00 cu
17 17 011100 -- N8 No_Module FC
18 18 011200 -- N8 No_Module FC
19 19 011300 -- N8 No_Module FC
20 20 011400 id N8 Online FC E
21 21 011500 -- N8 No_Module FC
22 22 011600 -- N8 No_Module FC
0 23 010000 id N4 Online FC F
ALE044120T2:admin>
- 195 -